96 matches found
iLevel Shear Panel for residential construction of shear walls and ...

The outstanding performance of TJ®-Shear Panels comes from a balanced design
approach that can help save lives and minimize home damage during earthquakes
...

http://www.ilevel.com/walls/w_tj_shear_panel.aspx
Shear Brace Specifier's Guide

The iLevel® Shear Brace (iSB) is a specially designed, prefabricated, engineered
- wood panel that helps structures resist lateral forces such as those ...

http://www.ilevel.com/literature/TJ-8620.pdf
iLevel Edge and Edge Gold Floor Panels Specifier's Guide

Shear-through-the-Thickness. Bending. Nail or Screw Design Values e. Design
values for nails or screws used with iLevel® Edge™ and. Edge Gold™ panels can be
...

http://www.ilevel.com/literature/OSB-4000.pdf
TB-154 - Edge and Edge Gold Floor Panels (Canada)

guidelines and load tables for Structurwood panels based on industry-standard
... Shear Through. Thickness, vp (lb/in of shear-resisting panel length) ...

http://www.ilevel.com/literature/TB-154.pdf
Brace Walls - no problem with the iLevel Shear Brace with ...

The iLevel Shear Brace is the first pre-fabricated shear panel to receive ICC-ES
2009 IBC/IRC code compliance verification (ESR-2652). ...

http://www.ilevel.com/walls/w_Shear-Brace.aspx
TB-209 - Sizing iLevel® Trus Joist® Products for Multi ...

Lateral Design - The iLevel Shear Brace (iSB) is a prefabricated shear panel
that can provide a solution for wall areas too narrow to allow a ...

http://www.ilevel.com/literature/TB-209.pdf
James Hardie Siding Products

Structurally sound as a shear panel. Also combine with Harditrimо planks for an
attractive board-and-batten look. ■ Manufactured with exclusive PrimePlusо ...

http://www.ilevel.com/literature/JH%2090016.pdf
TB-157 - iLevel Edge and Edge Gold Floor Panels (Canada)

OSB for TJI Joistsо as web-stock and iLevelо Edge Gold as floor panels. ....
Shear Through. Thickness, vp (lb/in of shear-resisting panel length) ...

http://www.ilevel.com/literature/TB-157.pdf
Code Evaluation Report - Prefabricated Wood I-Joist

Mar 14, 2005 ... recognized in the referenced listing, for the joist series used as the blocking
panel. Shear transfer nailing shall be established by design ...

http://www.ilevel.com/literature/AC23-1.pdf
12627-R TimberStrandо LSL

compression edge, and an end wall or shear transfer panel capable of
transferring a minimum unfactored uniform load of 730 N/m or the required shear
forces ...

http://www.ilevel.com/literature/CCMC12627-R.pdf